LabTech M10 Quantitative Parallel Concentrator

M10 Quantitative Parallel Concentrator is a fast and convenient sample concentrator. While saving valuable laboratory fume hood resources, it offers easy operation, unattended use, automatic concentration completion notification, and short evaporation time. It can replace traditional rotary evaporators, common nitrogen blowdown concentrators, and other concentration devices.

Key Features

M10 Quantitative Parallel Concentrator is simple and convenient to operate, with high concentration efficiency and excellent performance.
  • 10 sample channels can operate simultaneously or independently.
  • Compatible with 200 mL and 50 mL concentration cups; 200 mL and 50 mL cups can be used simultaneously.
  • Vortex nitrogen blowing: according to concentration cup size and sample volume, nitrogen blowing position and angle can be easily adjusted to optimize concentration speed.
  • Front window design allows visual monitoring of concentration progress, eliminating the cumbersome step of removing cups to check volume as required by other similar products.
  • Sealed and environmentally friendly, no need to install inside a fume hood.
  • Automatic End-Point detection, stable and reliable.
  • Water level and pressure over-limit alarms for convenience and safety.
  • User interface with touch screen, friendly and easy to operate.
Environmental
Used for enrichment and concentration of semi-volatile organic pollutants in soil, solid waste, atmosphere, and water samples in environmental monitoring.

HJ 834-2017: Determination of semi-volatile organic compounds in soil and sediment — GC-MS

HJ 805-2016: Determination of polycyclic aromatic hydrocarbons in soil and sediment — GC-MS

HJ 743-2015: Determination of polychlorinated biphenyls in soil and sediment — GC-MS

HJ 478-2009: Determination of polycyclic aromatic hydrocarbons in water — Liquid-liquid extraction and solid-phase extraction with HPLC

HJ 646-2013: Determination of polycyclic aromatic hydrocarbons in environmental air and exhaust gas — GC-MS

HJ 956-2018: Determination of benzo[a]pyrene in environmental air — HPLC

HJ 782-2016: Extraction of organics in solid waste — Pressurized fluid extraction
Food & Beverage
Used for enrichment and concentration of pesticide residues, veterinary drug residues, and other organic compounds in food, grains, and agricultural products.

GB 31658.5-2021: National Food Safety Standard — Determination of florfenicol and florfenicol amine residues in animal-derived foods — LC-MS/MS

GB 23200.112-2018: National Food Safety Standard — Determination of nine carbamate pesticides and metabolites in plant-based foods — LC post-column derivatization

GB/T 5009.19-2008: Determination of multi-residue organochlorine pesticides in food

GB/T 20770-2008: Determination of 486 pesticides and related chemicals in grains — LC-MS/MS

GB 23200.113-2018: National Food Safety Standard — Determination of 208 pesticides and metabolites in plant-based foods — GC-MS

GB/T 23376-2009: Determination of multiple pesticide residues in tea — GC/MS
Pharmaceutical & Medical
Used for enrichment and concentration of pesticide residues, mycotoxins, and other organic compounds in traditional Chinese medicine samples.

Chinese Pharmacopoeia 2020 Edition, Part IV, General Rules 2341 (Pesticide residue determination) and 2351 (Mycotoxin determination)
Disease Control
Used for enrichment and concentration of pesticide residues, veterinary drug residues, and semi-volatile organic compounds in food, agricultural products, and drinking water samples.

GB 31658.5-2021: National Food Safety Standard — Determination of florfenicol and florfenicol amine residues in animal-derived foods — LC-MS/MS

GB 23200.112-2018: National Food Safety Standard — Determination of nine carbamate pesticides and metabolites in plant-based foods — LC post-column derivatization

GB/T 5009.19-2008: Determination of multi-residue organochlorine pesticides in food

GB/T 20770-2008: Determination of 486 pesticides and related chemicals in grains — LC-MS/MS

GB 23200.113-2018: National Food Safety Standard — Determination of 208 pesticides and metabolites in plant-based foods — GC-MS

GB/T 23376-2009: Determination of multiple pesticide residues in tea — GC/MS
Geology & Mining
Used for enrichment and concentration of semi-volatile organic pollutants in soil, solid waste, atmosphere, and water samples in environmental monitoring.

HJ 834-2017: Determination of semi-volatile organic compounds in soil and sediment — GC-MS

HJ 805-2016: Determination of polycyclic aromatic hydrocarbons in soil and sediment — GC-MS

HJ 743-2015: Determination of polychlorinated biphenyls in soil and sediment — GC-MS

HJ 478-2009: Determination of polycyclic aromatic hydrocarbons in water — Liquid-liquid extraction and solid-phase extraction with HPLC

HJ 646-2013: Determination of polycyclic aromatic hydrocarbons in environmental air and exhaust gas — GC-MS

HJ 956-2018: Determination of benzo[a]pyrene in environmental air — HPLC

HJ 782-2016: Extraction of organics in solid waste — Pressurized fluid extraction
Forensics
Used for enrichment and concentration of drugs and organic pollutants in blood, urine, sewage, and other samples in criminal investigations and law enforcement.
Environmental
Food & Beverage
Pharmaceutical & Medical
Disease Control
Geology & Mining
Forensics
LabTech M10 Quantitative Parallel Concentrator

Related Products

Online Inquiry

Contact Us Linkedin Feedback
TOP

BackTop

What was the purpose of your visit today?
How can we improve your labtechus.com experience?
Please rate your labtechus.com experience:
Not Satisfied Extremely Satisfied
1 2 3 4 5 6 7 8 9 10

Your feedback is for internal use only, View the LabTech Privacy Policy.

If your request requires a reply from LabTech, please Contact Us.